Main purpose – preventing thermal losses down. Heat should go up in the warm for pex tubing. It can range from any products allowed the structure as a thermal insulating layer for use in the construction of gender.From whatever product is carried out layer of insulation should fulfill the following problem:

The thermal resistance of the insulation layer need to be higher than the overall pex tubes thermal resistance of the heating layers (consisting of completing covering, pex tubing) with an optimum warm load of Radiant Floor Heating. The higher the home heating lots, the thicker layer of insulation.The higher the thermal resistance of the finishing covering, the thicker layer of insulation.

The most common insulation material in contemporary building is Pex polystyrene. We advise using Pex polystyrene thickness of not less than 35 kg/m3 (pex tubing). Pex Polystyrene reduced density is not immune to mechanical anxiety, is damaged when not utilized meticulously, and also loses its mechanical as well as thermal shielding residential properties, especially versus the backdrop of the continuous civil design jobs is a very long time from completion of the pipeline setting up devices pex tubes Radiant Flooring Heating water to fill their earphones. Pex Polystyrene density of 50 kg/m3, as well as extrusion, is made use of in systems with high mechanical lots (automobile facilities, stockroom complexes with hefty loaders, warmed roads, etc.).

Enhancing fabric. Pex Rails

Reinforcing mesh step as well as the cell diameter of bar enhancing mesh is chosen on the basis of floor building and construction, based on the features of the facilities (pex tubes ), its destination, loads, etc. In the basic layout for less complicated setup used a grid, usually with a cell 150×150 mm, pole 4-5 mm. Falls on Pex polystyrene is a genuine cause for the layout contours water Radiant Flooring Home heating. Pex Pipeline are attached to the grid with plastic bolts.

To give added stamina screed in some cases is double support: a second layer of strengthening mesh is positioned on the shapes of water pipes Radiant Flooring Heating. Pex Bed Rails in Europe as a result of the huge spread of type stacking “serpent” is commonly made use of installing rails and also clips, which are arranged on polystyrene.

In some cases fixing enhancing mesh and/or placing rails made use of Pex U-shaped supports. Pex pipe contours vschelkivaetsya mounting rails in the ports (pex tubes slots). In this case, apply one layer of support, are laid over the pipes.

Pex Damping tape

Damping tape is positioned around the perimeter of the facilities before pouring concrete. Serves to compensate for thermal growth of concrete connections during home heating. It is created, generally polyethylene foam width of 100-120 mm as well as a density of 8-10 mm.

Pex Pipes

Pipes contours Radiant Floor Home heating stacked according to the illustration (draft Water Radiant Flooring Heating). The number of meters of the pipeline is recorded as well as taped in the table balancing reservoir, attached to the task. Based upon the evidence of placing architectural designer selects the need to readjust the adjusting (balancing) of the pex tubes table. Generally, unlike the actual length of pipe from the project by as much as 10%, the change harmonizing storage tank is not called for.

Hydrotesting

Prior to loading the shapes of water Radiant Flooring Home heating concrete is suggested to examine the system for rigidity. Examining the system is executed in accordance with nationwide structure policies. Usually, the system inspects the pressure of 3.4 bar for 1 day.

When filling Pex coolant system regular opening and also closing circuits. Acquire full removal of air from Pex pipelines and also devices.

It is recommended to leave the system of Radiant Floor Heating under pressure on the whole training course of the staying civil design works (device couplers, mounting finishing layers), occasionally keeping an eye on the level of pressure that, at any phase be sure that throughout the production of various other jobs, not a leakproof system.

Concrete screed

Putting concrete is executed after installing the shapes of water Radiant Flooring Home heating and screening tasks. The density of the screed have to go to least 30mm over the pipeline, mark the concrete recommended no less than the M-300 (V-22, 5). In grandfather clauses (big weight and/or thermal loads on the home heating oven, etc.) thickness of concrete connections and also brand developers determined based on the characteristics of the item (in this case necessarily is a different calculation of the heating panels). The minimum density of screed (30mm above the pipe) is attributable mostly to not-strength features, and also to attain harmony of temperature distribution externally of the heating panels.

When the density of screed over 150mm requires different estimations of the thermal regimen of the Pex heating panel with the introduction of unique modification factors.

For recommendation: the weight of 1 square meter of ties with the 50 mm thickness is 350-400 pound.

The higher the thickness of the connection the even more time is required to present it on a stable home heating regime from the moment of incorporation.

Thicker screed equates to better immersion system. The lower the thermal conductivity of connections, the higher the called for temperature of the coolant.

Countervailing joints If, about the excellent extent of the heating panel, it is separated (every 15 meters) partly of offsetting stitches, the tube, the back-crossing joint is laid in a protective corrugated tube (300mm left wing and right of the joint extension). It is recommended to load home heating circuits undamaged within a countervailing land, ie growth joints must go across just stress as well as return piping circuit.

The system of warm water allows the use of any type of plasticizers in concrete. Widely utilized in modern building and construction has actually gotten a device with plastic tie fibrils.